Substation-Rated, Enhanced Security SCADA-Aware Ethernet Layer 2 Managed Switch/Layer 3 Router With Optional 2G/3G & 4G LTE Cellular Radio Link, Enhanced Network Security, Terminal Server, PoE+, and 100FX SFP Ports

RLGE2FE16R

Availability: Worldwide

PDF Datasheet: en  
pdfManualpdfQuick Start

icon

Substation

icon

DIN Rail

icon

FLEXIBILITY

icon

-40 º to +85 ºC

icon

LAYER 3

icon

Firewall

icon

Gigabit Uplinks

icon

16

icon

2

icon

WARRANTY

Reliance

ComNet product series RLGE2FE16R are substation-rated and industrially hardened layer 2 managed switches/layer 3 routers, with a unique and highly robust packet processing SCADA-aware security firewall for the most missioncritical and demanding cyber-security applications. The RLGE2FE16R is intended for deployment in environments where high levels of electromagnetic noise and interference (EMI) and severe voltage transients and surges are routinely encountered, such as electrical utility substations and switchyards, heavy manufacturing facilities, track-side electronic equipment, and other difficult out-of-plant installations. Layer 3 routing functionality allows for the participation and foundation of a core network infrastructure. The RLGE2FE16R is an ideal platform for deploying a secure communications and networking gateway for remote electrical utility sites, and other critical infrastructure applications.

Features

  • Fully compliant with the requirements of IEC 61850-3 and IEEE 1613 Class 2, for use in electrical utility substations; and NEMA TS-1/TS-2 for Traffic Signal Control Equipment
  • For NERC-CIP-5 and NERC-CIP-014 compliance, or any network application demanding effective cyber-security protection
  • Optional internal 2G/3G/4G LTE GPRS/UMTS cellular radio modem with 2 SIM card slots, for maximum network reliability and availability
  • Highly advanced and sophisticated security suite: Per Port Deep Packet Inspection (DPI) SCADA-aware firewall supports DNP-3, ModBus, IEC 104/101, and IEC 61850 protocols for NERC-CIP-5 compliance
  • Network Learning allows the user to easily create secure and highly effective SCADA firewall rules
  • IEEE 802.1X Port-based network access control
  • L-2/3/4 ACL for incoming traffic, and layer 2/layer 3 VPN with IPsec
  • Fault/event notification provided through Syslog and SNMP traps
  • Up to (16) 10/100 Mbps Ethernet RJ-45 communications ports, with (2) 100/1000 Mbps SFP uplink ports. Available with optional (8) 100 Mbps SFP ports for network aggregation applications, or where it is desirable to provide optical connectivity directly to the switch/router or in electrically noisy environments.
  • Optional serial interface supports 4 ports of RS-232 serial data, with serial gateway and serial tunneling
  • Optional PoE+: 30 watts per port, 8 ports max.
  • Supports IEEE 1588v2 Precision Timing Protocol, Transparent Clock (TC), 10/100 Mbps communications ports only. (Gigabit uplink ports to be supported in future firmware release.)
  • The user APA (Authentication Proxy Access) controls remote access and communications to end-point/edge of network devices by all users, with extreme granularity across the users, time, physical Ethernet or serial data ports, TCP ports, and SCADA protocols. It also provides PCAP for the entire allowed maintenance or access session.
  • IPsec VPN with X.509 certificates, for use over any cellular or fiber-optic network
  • Ethernet layer 2 switching & layer 3 IP routing with integrated VPN and link protection per ITU-T G.8032
  • Internal/self-contained universal power supply: Available in operating voltage ranges from 9 to 270 VDC, or 90 to 250 VAC.
  • Redundant power supply input capability significantly reduces the possibility of a single-point-of-failure, for the highest possible system and network reliability (DC-powered units only)
  • No fans or forced-air cooling; cooling via natural convection eliminates unreliable and troublesome fans/moving parts, with no periodic maintenance requirements.
  • Electrical port supports both auto-negotiation of data speeds and automatic MDI/MDI-X crossover for full and half-duplex operation.

Application Diagram(s) (7)

Application Diagram(s) for RLGE2FE16RApplication Diagram(s) for RLGE2FE16RApplication Diagram(s) for RLGE2FE16RApplication Diagram(s) for RLGE2FE16RApplication Diagram(s) for RLGE2FE16RApplication Diagram(s) for RLGE2FE16RApplication Diagram(s) for RLGE2FE16R

Ordering Information

Part NumberDescription
RLGE2FE16R/S/22/28RLGE2FE16R with 2 × 100/1000 FX SFP, 8 × 10/100 TX, 220 VDC
RLGE2FE16R/S/22/28PRLGE2FE16R with 2 × 100/1000 FX SFP, 8 × 10/100 TX PoE+, 220 VDC
RLGE2FE16R/S/22/216RLGE2FE16R with 2 × 100/1000 FX SFP, 16 × 10/100 TX, 220 VDC
RLGE2FE16R/S/22/216PRLGE2FE16R with 2 × 100/1000 FX SFP, 8 × 10/100 TX PoE+, 8 × 10/100 TX, 220 VDC
RLGE2FE16R/S/22/288RLGE2FE16R with 2 × 100/1000 FX SFP, 8 × 10/100 TX, 8 × 100 FX SFP, 220 VDC
RLGE2FE16R/S/22/288PRLGE2FE16R with 2 × 100/1000 FX SFP, 8 × 10/100 TX PoE+, 8 × 100 FX SFP, 220 VDC
RLGE2FE16R/EReplace /S with /E in part code for Enhanced Security software package (extra charge)
RLGE2FE16R/S/48/28RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 48 VDC PSU; For -40 - +75°C
RLGE2FE16R/S/48/28/S22RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 2G/3G GPRS/UMTS modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 2G/3G HSPA+ modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 4G LTE (NA Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 4G LTE (EU Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/S22/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/S22/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G HSPA+ modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/S22/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28/S22/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28PRLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/S22RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G GPRS/UMTS modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G HSPA+ modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (NA Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (EU Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/S22/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/S22/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G HSPA+ modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/28P/S22/CNARLGE2FE16R system with 2 x SFP, 8 x10/100TX PoE, 4 x RS-232, cellular 4G LTE (NA Bands) modem,48V DC PSU; For -40 °C- +75°C
RLGE2FE16R/S/48/28P/S22/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 48 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/48/216RLGE2FE16R system with 16 × 10/100TX, 2 × GE SFP, 48 VDC PSU
RLGE2FE16R/S/48/216PRLGE2FE16R system with 8 × 10/100TX PoE, 8 × 10/100TX, 2 × GE SFP, 48 VDC PSU
RLGE2FE16R/S/48/288RLGE2FE16R system with 8 × 10/100TX, 8 × 100FX SFPs, 2 × GE SFP, 48 VDC PSU
RLGE2FE16R/S/48/288PRLGE2FE16R system with 8 × 10/100TX PoE, 8 × 100FX SFPs, 2 × GE SFP, 48 VDC PSU
RLGE2FE16R/S/24/28RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/S22RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 2G/3G GPRS/UMTS modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 2G/3G HSPA+ modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 4G LTE (NA Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 4G LTE (EU Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/S22/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/S22/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G HSPA+ modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/S22/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28/S22/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28PRLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/S22RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G GPRS/UMTS modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G HSPA+ modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (NA Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (EU Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/S22/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/S22/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G HSPA+ modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/S22/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/28P/S22/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 24 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/24/216RLGE2FE16R system with 16 × 10/100TX, 2 × GE SFP, 24 VDC PSU
RLGE2FE16R/S/24/216PRLGE2FE16R system with 8 × 10/100TX PoE, 8 × 10/100TX, 2 × GE SFP, 24 VDC PSU
RLGE2FE16R/S/24/288RLGE2FE16R system with 8 × 10/100TX, 8 × 100FX SFPs, 2 × GE SFP, 24 VDC PSU
RLGE2FE16R/S/24/288PRLGE2FE16R system with 8 × 10/100TX PoE, 8 × 100FX SFPs, 2 × GE SFP, 24 VDC PSU
RLGE2FE16R/S/12/28RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/S222 × SFP, 8 × 10/100TX, 4 × RS-232, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/S22RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 2G/3G GPRS/UMTS modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/CGU2 × SFP, 8 × 10/100TX, cellular 2G/3G GPRS/UMTS modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 2G/3G HSPA+ modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/282 × SFP, 8 × 10/100TX, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/CH+2 × SFP, 8 × 10/100TX, cellular 2G/3G HSPA+ modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 4G LTE (NA Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/CNA2 × SFP, 8 × 10/100TX, cellular 4G LTE (NA Bands) modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, cellular 4G LTE (EU Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/CEU2 × SFP, 8 × 10/100TX, cellular 4G LTE (EU Bands) modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/S22/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/S22/CGU2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/S22/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G HSPA+ modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/S22/CH+2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G HSPA+ modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/S22/CNA2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/S22/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28/S22/CEU2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28/S22/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (EU Bands) modem,12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P2 × SFP, 8 × 10/100TX PoE, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28PRLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/S222 × SFP, 8 × 10/100TX PoE, 4 × RS-232, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28P/S22RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/CGU2 × 100/1000FX SFP, 8 × 10/100TX, 4 × RS-232, 2G/3G GPRS/UMTS Cellular Modem, AC
RLGE2FE16R/S/12/28P/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G GPRS/UMTS modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28P/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular HSPA+ modem, 12 VDC PSU; For -40 º - +75 °C
RLGE2FE16R/S/11/28P/CH+2 × 100/1000FX SFP, 8 × 10/100TX, 4 × RS-232, 2G/3G HSPA+ Cellular Modem, AC
RLGE2FE16R/S/12/28P/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (NA Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/CNA2 × 100/1000FX SFP, 8 × 10/100TX, 4 × RS-232, 4G LTE Cellular Modem (NA Bands), AC
RLGE2FE16R/S/12/28P/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (EU Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/CEU2 × 100/1000FX SFP, 8 × 10/100TX, 4 × RS-232, 4G LTE Cellular Modem (EU Bands), AC
RLGE2FE16R/S/12/28P/S22/CGURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/S22/CGU2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G GPRS/UMTS modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28P/S22/CH+RLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G HSPA+ modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/S22/CH+2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G HSPA+ modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28P/S22/CNARLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/S22/CNA2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (NA Bands) modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/28P/S22/CEU2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 110 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/12/28P/S22/CEURLGE2FE16R system with 2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (EU Bands) modem, 12 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/11/21616 × 10/100TX, 2 × GE SFP, 110 VDC PSU
RLGE2FE16R/S/12/216RLGE2FE16R system with 16 × 10/100 BaseT, 2 × GE SFP, 12 VDC PSU
RLGE2FE16R/S/24/288P8 × 10/100TX PoE, 8 × 100FX SFPs, 2 × GE SFP, 12 VDC PSU
RLGE2FE16R/S/11/216P8 × 10/100TX PoE, 8 × 10/100TX, 2 × GE SFP, 110 VDC PSU
RLGE2FE16R/S/12/216PRLGE2FE16R system with 8 × 10/100TX PoE, 8 × 10/100TX, 2 × GE SFP, 12 VDC PSU
RLGE2FE16R/S/11/2888 × 10/100TX, 8 × 100FX SFPs, 2 × GE SFP, 110 VDC PSU
RLGE2FE16R/S/12/2888 × 10/100TX, 8 × 100FX SFPs, 2 × GE SFP, 12 VDC PSU
RLGE2FE16R/S/11/288P8 × 10/100TX PoE, 8 × 100FX SFPs, 2 × GE SFP, 110 VDC PSU
RLGE2FE16R/S/22/282 × SFP, 8 × 10/100TX, 220 VDC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/282 × SFP, 8 × 10/100TX, AC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/S222 × SFP, 8 × 10/100TX, 4 × RS-232, AC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/CGU2 × SFP, 8 × 10/100TX, cellular 2G/3G GPRS/UMTS modem, AC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/CH+2 × SFP, 8 × 10/100TX, cellular 2G/3G HSPA+ modem, AC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/CAN2 × SFP, 8 × 10/100TX, cellular 4G LTE (NA Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/CEURLGE2FE16R/S/AC/28/CEU
RLGE2FE16R/S/AC/28/S22/CGU2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G GPRS/UMTS PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/S22/CH+2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 2G/3G HSPA+ PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/S22/CNA2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (NA Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28/S22/CEU2 × SFP, 8 × 10/100TX, 4 × RS-232, cellular 4G LTE (EU Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P2 × SFP, 8 × 10/100TX PoE, AC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/S222 × SFP, 8 × 10/100TX PoE, 4 × RS-232, AC PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/CGU2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G GPRS/UMTS PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/CH+2 × SFP, 8 × 10/100TX PoE, cellular 2G/3G HSPA+ PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/CNA2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (NA Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/CEU2 × SFP, 8 × 10/100TX PoE, cellular 4G LTE (EU Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/S22/CGU2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G GPRS/UMTS PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/S22/CH+2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 2G/3G HSPA+ PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/S22/CNA2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular4G LTE (NA Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/28P/S22/CEU2 × SFP, 8 × 10/100TX PoE, 4 × RS-232, cellular 4G LTE (EU Bands) PSU; For -40 ° - +75 °C
RLGE2FE16R/S/AC/2162 × 100/1000FX SFP, 16 × 10/100TX, AC
RLGE2FE16R/S/AC/216P2 × 100/1000FX SFP, 8 × 10/100TX PoE+, 8 × 10/100TX, AC
RLGE2FE16R/S/AC/2882 × 100/1000FX SFP, 8 × 10/100TX, 8 × 100FX SFP, AC
RLGE2FE16R/S/AC/288P2 × 100/1000FX SFP, 8 × 10/100TX PoE+, 8 × 100FX SFP, AC
/EEnhanced Security Option

* Small Form-Factor Pluggable Module. Sold separately.